PPS Docs

Table of Contents

Cover Page

0 . Introduction

          0.0 - Symbols

          0.01 - Screen Help

          0.02 - Warnings

1. Pump Station System Setup

          1.00 - Pump Station Name

          1.01 - Activation Code

          1.02 - Set Clock

          1.03 - User

          1.02 - VFD Feedback

          1.03 - Jockey Hand Speed

          1.02 - Well const. speed

          1.03 - MAC Used

          1.03 - System Setup screen 1

          1.03 - System Setup screen 2

2. Setup Pump Drive Configuration

          2.00 - Jockey Pump Setup

          2.01 - Main Pump(s) Setup

          2.02 - Intermediate Pump Setup

          2.03 - Well Pump Setup

          2.04 - Recirc Pump Setup

          2.05 - Primer Pump Setup

          2.06 - Injection Pump Setup

4. Main Screen Navigation

          4.00 - Pump monitoring

          4.01 - AI monitoring

          4.02 - Output monitoring

          4.03 - 3 – Trend

          4.04 - 4 – Faults

          4.05 - 5 – Menu

          4.06 - Banner, Language, Time & Date, PLC Battery, Version, E-stop

5. Pump operation

          5.00 - 3 - Jockey Pump Settings

          5.01 - 92 - Intermediate pump (MID Pump) Settings

          5.02 - 4 - Main Pump(s) Settings

          5.03 - 1 - Well Pump Settings

          5.04 - 27 - Recirc pump

          5.05 - 21 - Primer Pump

          5.06 - 94 – Primer Pump settings also

          5.07 - 150 – Jockey Primer Pump

          5.08 - 155 – Intermediate Primer Pump

          5.09 - 151 to 154 – Main Primer Pump

          5.10 - 74 – Injection Pump Settings

6.  Analog Inputs

          6.00 - 37 - Panel Temp Settings

          6.01 - 14 - Fill Flow meter

          6.02 - 217 - Well source level

          6.03 - 33 - Well PSI

          6.04 - 34 - Well Flow meter

          6.05 - 40 - Source level

          6.06 - 41 - Intake PSI

          6.07 - 32 - Pre-filter PSI

          6.08 - 42 - Discharge PSI

          6.09 - 43 - Station Flow meter

          6.10 - 214 - Recirc PSI

          6.11 - 215 - Recirc Flow

          6.12 - 36 - Destination level

          6.13 - 13 - Injector flow meter

          6.14 - 210 - Filter flow meter

          6.15 - 211 - PH sensor

          6.16 - 212 - Conductivity sensor           

          6.17 - 216 – Intake Leak flow meter

          6.18 - 218 - Pre-WYE PSI

Screens

Intermediate pump settings

  1. 61 - Intermediate Pump Flow settings

Jockey Pump Settings

  1. 62 – Jockey Flow settings
  2. 70 - Jockey Pump Permissive
  3. 71 – Intermediate Pump Permissive

Main Pump Operation

  1. 58 – Alternation Settings
  2. 63 – Lag Settings
  3. 93 – Pump Valve Settings
  4. 64 – Main Pump Permissive
  5. 157 – Motor CT settings

Well Pump Operation

  1. 68 – Well Pump Permissive
  2. 77 – Well Configuration
  3. 78 – Well Sleep settings
  4. 167 – Well Process Control Screen
  5. 168 – Well Fill Mode
  6. 169 – Well Artesian Valve

Recirculation Pump Settings

  1. 146 - Recirc remote start
  2. 147 – Recirc Communication

Valves

  1. 2 - CW Valve settings
  2. 28 - Filters
    1. 8 - Filter Settings
    2. 30 – Filters
    3. 80 – Filter #1
  3. 300 – Prime Assure Valve
    1. 301 – Prime assure valves
  4. 11 - Master Valve
  5. 148 – Altitude Valve Settings
  6. 165 – Pump Injection valves
  7. 159 – Scrubber Valve
  8. 79 – Fill valve configuration
    1. 12 - Fill valve
    2. 149 – Fill Device Settings
    3. 160 to 165 Fill devices

Station Settings

  1. 53 - Harmonics
  2. 35 – Underload Settings
  3. 73 - Overcycle Settings
  4. 60 – Sleep Settings
    1. 183 – Sleep settings again?
  5. 44 – Fill Mode Settings
  6. 45 - Remote start
  7. 18 - Wye strainer
  8. 121 – Advanced Setpoint settings
  9. 95 – Filter groups
    1. 96 – Filter group 1
    2. 97 – Filter group 2
    3. 97 – Filter group configuration

Advanced Setting Adjustments 

  1. 31 - PID settings
  2. 167 – Well PID settings
  3. 39 – PID Trim Mode Settings

Other

  1. 29 - AIO Screen
  2. 19 - IO Screen
  3. 38 - Prime Loss Settings
  4. 166 – Self Prime settings
  5. 120 – Silence Alarm
  6. 184 – Float orientation
  7. 213 – Enclosure Temp Settings
  8. 59 – Rain Event
  9. 69 – Monthly Totals
  10. 72 – Daily Totals
  11. Scheduler
    1. 23 – Scheduler 1
    2. 24 – Scheduler 2
    3. 25 – Scheduler 3
  12. 100 – WARNING Pumps in hand
  13. 115 – PLC Not in run mode
  14. 46 – Password Protect
  15. 47 – Activation Screen
    1. 126 – Activation Message
  16. 48 – Set Clock
  17. 75 – Email settings
  18. 76 – Email SMTP Server settings
  19. 49 – Load/Save Defaults
  20. 57 - Backup Management
  21. 56 – VFD Bypass settings
  22. 20 – USB Data

System Setup

  1. 140 – Input Reference Help

    1. 141 – Input reference help
  2. 142 – Output Reference Help

    1. 143 - Output Reference help
  3. 144 - Analog Input ref. help

  4. 145 – Analog output ref. help

  5. 182 – USB or SD Missing

  6. 400 – Cloud1 (Select correct screen size)

  7. 401 – Cloud2 (Download Update)

  8. 402 – Cloud3 (Error Occurred)

  9. 403 – Cloud4 (Remove USB and Replace it)

  10. 404 – Battery Help Page

  11. 405 – BACnet Menu

    1. 406 - BACnet Menu 2
  12. 407 – Pump Down Operation

  13. 181 – SCADA Main

  14. 176 – SCADA Setup

    1. 177 – SCADA out help 1
    2. 178 - SCADA out help 2
    3. 179 - SCADA out help 3
  15. 99 – SCADA IO

    1. 180 – SCADA IO (Again)?
  16. 26 – Port 2 IP Config (SCADA)

  17. 22 – Custom (Bypass)

  18. 122 – RSLogix500

  19. 123 – Studio 5000

  20. 124 – Data Map RSLogix 500

  21. 125 – Modbus Map

    1. 128 – System Status Enum
      1. 158 – System Status Enum
    2. 129 – Device Status Enum

Where is this

  1. Bypass valve