PPS Docs

Rain Settings

If the area served by the pump station receives rainfall, rain sensor settings can prevent unnecessary watering, reduce costs, and help avoid overwatering or flooding after heavy rain. When a rain sensor or switch is installed, the panel can use that input to inhibit scheduled or automatic run cycles until conditions are dry, ensuring the system only operates when irrigation is required.



1.1 Rain Button


1.2 Rain Event

Rain Switch or Gauge

In the Rain Settings screen, tell the automation whether or not it is Gauge, or switch that the PLC is monitoring (image 1.3).  This will tell the PLC how to calculate the rainfall that is occurring and will display that number in the Current Rain Count display.

Switch: Sends a single pulse to the PLC when a preset volumetric event occurs (e.g., a tipping bucket pulse). Each pulse indicates enough rain has fallen to count toward a lockout trigger.

Gauge: Measures and accumulates rainfall continuously. Use the gauge thresholds (the value fields below) to set the rain event trigger and accumulation behavior.

1.3 Gauge or Switch

Trigger, Interval, and Off Delay

Rain Lockout — Settings and Operation (image 1.4)

Operation:

1.4 Trigger, interval, and delay

Force, Cancel, Status

Panel Rain Status (bottom of screen)

Controls:

1.5 Status